Skip to main navigation Skip to search Skip to main content

Sex and Population-Specific 99th Percentiles of Troponin for Myocardial Infarction in the Danish Population (DANSPOT)

  • Rasmus Bo Hasselbalch*
  • , Nicoline Jørgensen
  • , Jonas Kristensen
  • , Nina Strandkjær
  • , Thilde Olivia Kock
  • , Theis Lange
  • , Sisse Rye Ostrowski
  • , Janna Nissen
  • , Margit Hørup Larsen
  • , Ole Birger Vesterager Pedersen
  • , Mustafa Vakur Bor
  • , Shoaib Afzal
  • , Pia Rørbæk Kamstrup
  • , Morten Dahl
  • , Linda Hilsted
  • , Christian Torp-Pedersen
  • , Henning Bundgaard
  • , Kasper Karmark Iversen
  • *Corresponding author for this work

Research output: Contribution to journalArticleResearchpeer-review

Abstract

BACKGROUND: Sex- and population-specific 99th percentiles of high-sensitivity cardiac troponin (hs-cTn) are recommended in guidelines although the evidence for a clinical utility is sparse. The DANSPOT trial will investigate the clinical effect of sex- and population-specific 99th percentiles of cTn. We report the 99th percentiles derived from this trial and their dependency on kidney function.

METHODS: We used samples from healthy Danish blood donors and measured hemoglobin A1c, N-terminal pro-brain natriuretic peptide and creatinine, and calculated an estimated glomerular filtration rate (eGFR). We compared 2 cutoffs for the eGFR of healthy participants (60 vs 90 mL/min/1.73 m2). The cTn assays investigated were Siemens Atellica and Dimension Vista hs-cTnI, Abbott hs-cTnI, and Roche hs-cTnT.

RESULTS: A total of 2287 participants were sampled, of which 71 (3.1%) were excluded due to a history of heart disease (n = 4), insufficient material (n = 7), or a screening biomarker (n = 60). Of the remaining 2216 participants, 1325 (59.8%) had an eGFR ≥90 mL/min/1.73 m2. Compared to a cutoff of 60 mL/min/1.73 m2 for eGFR, using 90 mL/min/1.73 m2 resulted in lower 99th percentiles for females; Siemens Vista (46 vs 70 ng/L), Abbott (14 vs 18 ng/L), and Roche cTnT (10 vs 13 ng/L), and decreased the number of measurements above the manufacturers' 99th percentiles for all assays.

CONCLUSIONS: We present reference values for 4 cTn assays for eGFR cutoffs of 60 and 90 mL/min/1.73 m2. These cutoffs differ based on the eGFR threshold for inclusion indicating that any chosen cutoff is also valuable with moderately reduced kidney function.

Original languageEnglish
Pages (from-to)901-912
Number of pages12
JournalThe journal of applied laboratory medicine
Volume9
Issue number6
Early online date29 Aug 2024
DOIs
Publication statusPublished - 4 Nov 2024

Keywords

  • Adult
  • Aged
  • Biomarkers/blood
  • Denmark/epidemiology
  • Female
  • Glomerular Filtration Rate
  • Humans
  • Male
  • Middle Aged
  • Myocardial Infarction/diagnosis
  • Reference Values
  • Sex Factors
  • Troponin I/blood
  • Troponin T/blood
  • Troponin/blood
  • Thresholds
  • Sample
  • High-sensitivity troponin
  • Upper reference limits
  • Assays

Fingerprint

Explore the research areas of 'Sex and Population-Specific 99th Percentiles of Troponin for Myocardial Infarction in the Danish Population (DANSPOT)'.

Cite this