Abstract
PURPOSE: High intensity occupational physical activity (OPA) seem to aggravate health and increase risk of sick leave and early retirement. Most intensity of OPA monitoring has been self-reported, e.g. by rating of perceived exertion (RPE). However, no studies have investigated the precision and risk of bias in RPE reporting during free-living OPA. This study investigated the agreement between OPA intensity in percentage of the heart rate reserve (%HRR) estimated from RPE and device-measured heart rate (HR), and potential bias factors on this agreement.
METHODS: The CR10 scale measured RPE at work. The Actiheart monitor measured HR during 24-h a day for 2-4 days. Both RPE and device-worn HR were converted to %HRR. The difference between both %HRR and their limits of agreement was determined in a Bland Altman plot. To detect bias factors, the difference between both %HRR was regressed on age, sex, cardiorespiratory fitness, occupational lifting, medication, consequences of musculoskeletal disorders and the interactions between these factors with device-work %HRR.
RESULTS: Six hundred and twenty-three participants were included in the analysis. Mean difference between RPE-based and device-worn %HRR was 54.6% (SD 19.5). The limits of agreement were wide (11.6-90.1%HRR). Age (0.48%HRR, 95% CI 0.18-0.79) occupational lifting (9.84%HRR, 95% CI 3.85-15.83) and cardiorespiratory fitness (0.41%HRR, 95% CI 0.03-0.79) significantly biased the agreement between the estimations of OPA intensity.
CONCLUSION: RPE overestimated OPA intensity, and was biased by several factors. Device-worn %HRR should be preferred when evaluating OPA intensity among workers with physically demanding jobs.
| Original language | English |
|---|---|
| Pages (from-to) | 1293-1301 |
| Number of pages | 9 |
| Journal | European Journal of Applied Physiology |
| Volume | 122 |
| Issue number | 5 |
| Early online date | 10 Mar 2022 |
| DOIs | |
| Publication status | Published - May 2022 |
Keywords
- Physical Exertion/physiology
- Cardiorespiratory Fitness
- Heart Rate/physiology
- Humans
- Occupations
- Self Report
- Exercise/physiology
- Intensity
- Rate of perceived exertion
- Rating of physical work strain
- Heart rate
- Occupational physical activity
- Deterioration
- Physical activity at work
Fingerprint
Explore the research areas of 'Intensity of occupational physical activity in blue-collar workers: do self-reported rating and device-worn measurements agree?'.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver