Skip to main navigation Skip to search Skip to main content

Implant-based multi-parameter telemonitoring of patients with heart failure and a defibrillator with vs. without cardiac resynchronization therapy option: a subanalysis of the IN-TIME trial

  • Johann Christoph Geller
  • , Thorsten Lewalter
  • , Niels Eske Bruun
  • , Milos Taborsky
  • , Frank Bode
  • , Jens Cosedis Nielsen
  • , Christoph Stellbrink
  • , Steffen Schön
  • , Holger Mühling
  • , Hanno Oswald
  • , Sebastian Reif
  • , Stefan Kääb
  • , Peter Illes
  • , Jochen Proff
  • , Nikolaos Dagres
  • , Gerhard Hindricks
  • , For the IN-TIME Study Group

Research output: Contribution to journal › Article › Research › peer-review

Abstract

Aims: In the IN-TIME trial, automatic daily implant-based multiparameter telemonitoring significantly improved clinical outcomes in patients with chronic systolic heart failure and implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D). We compared IN-TIME results for ICD and CRT-D subgroups. Methods: Patients with LVEF ≤ 35%, NYHA class II/III, optimized drug treatment, no permanent atrial fibrillation, and a dual-chamber ICD (n = 274) or CRT-D (n = 390) were randomized 1:1 to telemonitoring or no telemonitoring for 12 months. Primary outcome measure was a composite clinical score, classified as worsened if the patient died or had heart failure-related hospitalization, worse NYHA class, or a worse self-reported overall condition. Results: The prevalence of worsened score at study end was higher in CRT-D than ICD patients (26.4% vs. 18.2%; P = 0.014), as was mortality (7.4% vs. 4.1%; P = 0.069). With telemonitoring, odds ratios (OR) for worsened score and hazard ratios (HR) for mortality were similar in the ICD [OR = 0.55 (P = 0.058), HR = 0.39 (P = 0.17)] and CRT-D [OR = 0.68 (P = 0.10), HR = 0.35 (P = 0.018)] subgroups (insignificant interaction, P = 0.58–0.91). Conclusion: Daily multiparameter telemonitoring has a potential to reduce clinical endpoints in patients with chronic systolic heart failure both in ICD and CRT-D subgroups. The absolute benefit seems to be higher in higher-risk populations with worse prognosis.

Original languageEnglish
Pages (from-to)1117-1127
Number of pages11
JournalClinical Research in Cardiology
Volume108
Issue number10
DOIs
Publication statusPublished - 1 Oct 2019
Externally publishedYes

Funding

We thank Bernd Br?sehaber for statistical calculations, J?rgen Schrader for data analysis and scientific input, and Dejan Danilovic for scientific input, critical reading of the manuscript, and editorial assistance.

Keywords

  • Remote monitoring of cardiac resynchronization therapy defibrillators
  • Remote monitoring of implantable cardioverter-defibrillators
  • Telemonitoring of patients with heart failure
  • Prospective Studies
  • Follow-Up Studies
  • Heart Failure, Systolic/mortality
  • Humans
  • Middle Aged
  • Risk Factors
  • Germany/epidemiology
  • Male
  • Stroke Volume/physiology
  • Treatment Outcome
  • Telemedicine/methods
  • Cause of Death/trends
  • Survival Rate/trends
  • Cardiac Resynchronization Therapy/methods
  • Defibrillators, Implantable
  • Female
  • Aged

Fingerprint

Explore the research areas of 'Implant-based multi-parameter telemonitoring of patients with heart failure and a defibrillator with vs. without cardiac resynchronization therapy option: a subanalysis of the IN-TIME trial'.

Cite this