Heat-washout: a new method for measuring cutaneous blood flow rate in areas with and without arteriovenous anastomoses

    Research output: Contribution to journalArticleResearchpeer-review

    Abstract

    A new method, the heat-washout method, for measuring total cutaneous blood flow rate is introduced. The measurements were performed with a transcutaneous (tc) PO2-electrode that is capable of heating and measuring local temperature, and it is constructed with a thermostatically controlled cap. The probe was heated electrically to a selected temperature 2-10 degrees above normal skin temperature. When the temperature was stable, the heating element was turned off, and the temperature was registered every 10 s until a stable baseline temperature, Tb, was obtained. Tb was subtracted from the registered temperatures giving deltaTs that were plotted in a semilogarithmic diagram. The heat-washout was monoexponential, and the slope was used for calculating blood flow rate in accordance with the principle of Kety, using a known partition coefficient. The method was applied to the forearm in two subjects, and the results were compared to blood flow rates obtained simultaneously by the 133Xe-washout method in the same area. The equation of the regression line was y = 2.5 + 0 x 968X and the correlation coefficient was 0 x 986 at temperature levels of 37-45 degrees C. In the pulp of the thumb, blood flow rates, in arteriovenous anastomoses, were estimated in two subjects by subtracting the capillary blood flow rate, measured by 133Xe-washout, from the total cutaneous blood flow rate, measured by heat-washout. Due to a relatively low diffusions coefficient for 133Xe compared to heat, 133Xe cannot be used for measurement of blood flow rate in arteriovenous anastomoses.

    Original languageEnglish
    Pages (from-to)259-74
    Number of pages16
    JournalClinical Physiology
    Volume16
    Issue number3
    DOIs
    Publication statusPublished - May 1996

    Keywords

    • Adult
    • Arteriovenous Anastomosis/physiology
    • Blood Gas Monitoring, Transcutaneous
    • Electrodes
    • Female
    • Fingers/blood supply
    • Humans
    • Male
    • Microcirculation/physiology
    • Middle Aged
    • Plethysmography, Impedance
    • Regional Blood Flow/physiology
    • Skin/blood supply
    • Temperature
    • Xenon Radioisotopes

    Fingerprint

    Explore the research areas of 'Heat-washout: a new method for measuring cutaneous blood flow rate in areas with and without arteriovenous anastomoses'.

    Cite this