Skip to main navigation Skip to search Skip to main content

Effect of Implantable Cardioverter-defibrillators in Nonischemic Heart Failure According to Background Medical Therapy: Extended follow-up of the DANISH trial

  • Adelina Yafasova*
  • , Seiko N Doi
  • , Jens Jakob Thune
  • , Jens C Nielsen
  • , Jens Haarbo
  • , Niels E Bruun
  • , Finn Gustafsson
  • , Hans Eiskjær
  • , Christian Hassager
  • , Jesper H Svendsen
  • , Dan E Høfsten
  • , Christian Torp-Pedersen
  • , Steen Pehrson
  • , Lars Køber
  • , Jawad H Butt
  • *Corresponding author for this work

Research output: Contribution to journalArticleResearchpeer-review

Abstract

BACKGROUND: The Heart Failure Collaboratory (HFC) score integrates types and dosages of guideline-directed pharmacotherapies for heart failure (HF) with reduced ejection fraction (HFrEF). We examined the effects of cardioverter-defibrillator (ICD) implantation according to the modified HFC (mHFC) score in 1116 patients with nonischemic HFrEF from the Danish Study to Assess the Efficacy of ICDs in Patients with Nonischemic Systolic HF on Mortality (DANISH).

METHODS AND RESULTS: Patients were assigned scores for renin-angiotensin-system inhibitors, beta-blockers and mineralocorticoid receptor antagonists (0, no use; 1, < 50% of maximum dosage; 2, ≥ 50% of maximum dosage). The maximum score was 6, corresponding to ≥ 50% of maximum dosage for all therapies. The median baseline mHFC score was 4, and the median follow-up was 9.5 years. Compared with an mHFC score of 3-4, an mHFC score of 1-2 was associated with a higher rate of all-cause death (mHFC = 1-2: adjusted HR 1.67 [95% CI, 1.23-2.28]; mHFC = 3-4, reference; mHFC = 5-6: adjusted HR 1.07 [95% CI, 0.87-1.31]). ICD implantation did not reduce all-cause death compared with control (reference) (HR 0.89 [95% CI, 0.74-1.08]), regardless of mHFC score (mHFC = 1-2: HR 0.98 [95% CI, 0.56-1.71]; mHFC = 3-4: HR 0.89 [95% CI,0.66-1.20]; mHFC = 5-6: HR 0.85 [95% CI, 0.64-1.12]; P interaction, 0.65). Similarly, ICD implantation did not reduce cardiovascular death (HR 0.87 [95% CI, 0.70-1.09]), regardless of mHFC score (P interaction, 0.59). The ICD group had a lower rate of sudden cardiovascular death (HR, 0.60 [95% CI,0.40-0.92]); this association was not modified by mHFC score (P interaction, 0.35).

CONCLUSIONS: Lower mHFC scores were associated with higher rates of all-cause death. ICD implantation did not result in an overall survival benefit in patients with nonischemic HFrEF, regardless of mHFC score.

Original languageEnglish
Pages (from-to)1411-1420
Number of pages10
JournalJournal of Cardiac Failure
Volume30
Issue number11
Early online date13 May 2024
DOIs
Publication statusPublished - Nov 2024

Fingerprint

Explore the research areas of 'Effect of Implantable Cardioverter-defibrillators in Nonischemic Heart Failure According to Background Medical Therapy: Extended follow-up of the DANISH trial'.

Cite this