Skip to main navigation Skip to search Skip to main content

Differential clinical outcomes after 1 year versus 5 years in a randomised comparison of zotarolimus-eluting and sirolimus-eluting coronary stents (the SORT OUT III study): A multicentre, open-label, randomised superiority trial

  • Michael Maeng*
  • , Hans Henrik Tilsted
  • , Lisette Okkels Jensen
  • , Lars Romer Krusell
  • , Anne Kaltoft
  • , Henning Kelbæk
  • , Anton B. Villadsen
  • , Jan Ravkilde
  • , Knud Nørregaard Hansen
  • , Evald Høj Christiansen
  • , Jens Aarøe
  • , Jan Skov Jensen
  • , Steen Dalby Kristensen
  • , Hans Erik Bøtker
  • , Leif Thuesen
  • , Morten Madsen
  • , Per Thayssen
  • , Henrik Toft Sørensen
  • , Jens Flensted Lassen
  • *Corresponding author for this work

Research output: Contribution to journalArticleResearchpeer-review

Abstract

Background: In head-to-head comparisons of coronary drug-eluting stents, the primary endpoint is traditionally assessed after 9-12 months. However, the optimum timepoint for this assessment remains unclear. In this study, we assessed clinical outcomes at up to 5 years' follow-up in patients who received two different types of drug-eluting stents. Methods: We undertook this multicentre, open-label, randomised superiority trial at five percutaneous coronary intervention centres in Denmark. We randomly allocated 2332 eligible adult patients (≥18 years of age) with an indication for drug-eluting stent implantation to the zotarolimus-eluting Endeavor Sprint stent (Medtronic, Santa Rosa, CA, USA) or the sirolimus-eluting Cypher Select Plus stent (Cordis, Johnson & Johnson, Warren, NJ, USA). Randomisation of participants was achieved by computer-generated block randomisation and a telephone allocation service. The primary endpoint of the SORT OUT III study was a composite of major adverse cardiac events-cardiac death, myocardial infarction, and target vessel revascularisation-at 9 months' follow-up. In this study, endpoints included the occurrence of major adverse cardiac events and definite stent thrombosis at follow-up times of up to 5 years. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT00660478. Findings: We randomly allocated 1162 patients to receive the zotarolimus-eluting stent and 1170 to the sirolimus-eluting stent. At 5-year follow-up, rates of major adverse cardiac events were similar in patients treated with both types of stents (zotarolimus-eluting stents 197/1162 [17·0%] vs sirolimus-eluting stents 182/1170 [15·6%]; odds ratio [OR] 1·10, 95% CI 0·88-1·37; p=0·40). This finding was indicative of the directly contrasting results for rates of major adverse cardiac events at 1-year follow up (zotarolimus 93/1162 [8·0%] vs sirolimus 46/1170 [3·9%]; OR 2·13, 95% CI 1·48-3·07; p<0·0001) compared with those at follow-up between 1 and 5 years (104 [9·0%] vs 136 [11·6%]; OR 0·78, 95% CI 0·59- 1·02; p=0·071). At 1-year follow-up, definite stent thrombosis was more frequent after implantation of the zotarolimus-eluting stent (13/1162 [1·1%]) than the sirolimus-eluting stent (4/1170 [0·3%]; OR 3·34, 95% CI 1·08-10·3; p=0·036), whereas the opposite finding was recorded for between 1 and 5 years' follow-up (zotarolimus-eluting stent 1/1162 [0·1%] vs sirolimus-eluting stent 21/1170 [1·8%], OR 0·05, 95% CI 0·01-0·36; p=0·003). 26 of 88 (30%) target lesion revascularisations in the zotarolimus-eluting stent group occurred between 1 and 5 years' follow-up, whereas 54 of 70 (77%) of those in the sirolimus-eluting stent group occurred during this follow-up period. Interpretation: The superiority of sirolimus-eluting stents compared with zotarolimus-eluting stents at 1-year follow-up was lost after 5 years. The traditional 1-year primary endpoint assessment therefore might be insufficient to predict 5-year clinical outcomes in patients treated with coronary drug-eluting stent implantation. Funding: Cordis and Medtronic.

Original languageEnglish
Pages (from-to)2047-2056
Number of pages10
JournalThe Lancet
Volume383
Issue number9934
DOIs
Publication statusPublished - 1 Jan 2014
Externally publishedYes

Funding

The study was supported by unrestricted research grants from Cordis and Medtronic. These companies had no role in the study design, data collection, data analysis, or data interpretation; had no access to the clinical trial database; and did not have the opportunity to review or comment on this report. The corresponding author had full access to all the data in the study and had final responsibility for the decision to submit for publication. MMae has received unrestricted research grants from Cordis (Johnson & Johnson) and Medtronic; travel grants from Medtronic and Abbott; and research grants from Biosensors, Boston Scientific Corp, Terumo, and Biotronic. LOJ has received grants from Biosensors, St Jude Medical, and Terumo, and personal fees from St Jude Medical. All the other authors declare that they have no competing interests. The SORT OUT III trial was supported by unrestricted research grants from Cordis and Medtronic. We are indebted to our assistant Helle Bargsteen for her efficient help with all aspects of the trial.

Fingerprint

Explore the research areas of 'Differential clinical outcomes after 1 year versus 5 years in a randomised comparison of zotarolimus-eluting and sirolimus-eluting coronary stents (the SORT OUT III study): A multicentre, open-label, randomised superiority trial'.

Cite this