TY - JOUR
T1 - The Effect of Insulin Degludec Versus Insulin Glargine U100 on Glucose Metrics Recorded During Continuous Glucose Monitoring in People With Type 1 Diabetes and Recurrent Nocturnal Severe Hypoglycemia
AU - Brøsen, Julie Maria Bøggild
AU - Agesen, Rikke Mette
AU - Alibegovic, Amra Ciric
AU - Andersen, Henrik Ullits
AU - Beck-Nielsen, Henning
AU - Gustenhoff, Peter
AU - Hansen, Troels Krarup
AU - Hedetoft, Christoffer
AU - Jensen, Tonny Joran
AU - Juhl, Claus Bogh
AU - Stolberg, Charlotte Røn
AU - Lerche, Susanne Søgaard
AU - Nørgaard, Kirsten
AU - Parving, Hans-Henrik
AU - Tarnow, Lise
AU - Thorsteinsson, Birger
AU - Pedersen-Bjergaard, Ulrik
PY - 2025/3
Y1 - 2025/3
N2 - AIM: Comparing continuous glucose monitoring (CGM)-recorded metrics during treatment with insulin degludec (IDeg) versus insulin glargine U100 (IGlar-100) in people with type 1 diabetes (T1D) and recurrent nocturnal severe hypoglycemia.MATERIALS AND METHODS: This is a multicenter, two-year, randomized, crossover trial, including 149 adults with T1D and minimum one episode of nocturnal severe hypoglycemia within the last two years. Participants were randomized 1:1 to treatment with IDeg or IGlar-100 and given the option of six days of blinded CGM twice during each treatment. CGM traces were reviewed for the percentage of time-within-target glucose range (TIR), time-below-range (TBR), time-above-range (TAR), and coefficient of variation (CV).RESULTS: Seventy-four participants were included in the analysis. Differences between treatments were greatest during the night (23:00-06:59). Treatment with IGlar-100 resulted in 54.0% vs 49.0% with IDeg TIR (70-180 mg/dL) (estimated treatment difference [ETD]: -4.6%, 95% confidence interval [CI]: -9.1, -0.0, P = .049). TBR was lower with IDeg at level 1 (54-69 mg/dL) (ETD: -1.7% [95% CI: -2.9, -0.5], P < .05) and level 2 (<54 mg/dL) (ETD: -1.3% [95% CI: -2.1, -0.5], P = .001). TAR was higher with IDeg compared with IGlar-100 at level 1 (181-250 mg/dL) (ETD: 4.0% [95% CI: 0.8, 7.3], P < .05) and level 2 (> 250 mg/dL) (ETD: 4.0% [95% CI: 0.8, 7.2], P < .05). The mean CV was lower with IDeg than that with IGlar-100 (ETD: -3.4% [95% CI: -5.6, -1.2], P < .05).CONCLUSION: For people with T1D suffering from recurrent nocturnal severe hypoglycemia, treatment with IDeg, compared with IGlar-100, results in a lower TBR and CV during the night at the expense of more TAR.
AB - AIM: Comparing continuous glucose monitoring (CGM)-recorded metrics during treatment with insulin degludec (IDeg) versus insulin glargine U100 (IGlar-100) in people with type 1 diabetes (T1D) and recurrent nocturnal severe hypoglycemia.MATERIALS AND METHODS: This is a multicenter, two-year, randomized, crossover trial, including 149 adults with T1D and minimum one episode of nocturnal severe hypoglycemia within the last two years. Participants were randomized 1:1 to treatment with IDeg or IGlar-100 and given the option of six days of blinded CGM twice during each treatment. CGM traces were reviewed for the percentage of time-within-target glucose range (TIR), time-below-range (TBR), time-above-range (TAR), and coefficient of variation (CV).RESULTS: Seventy-four participants were included in the analysis. Differences between treatments were greatest during the night (23:00-06:59). Treatment with IGlar-100 resulted in 54.0% vs 49.0% with IDeg TIR (70-180 mg/dL) (estimated treatment difference [ETD]: -4.6%, 95% confidence interval [CI]: -9.1, -0.0, P = .049). TBR was lower with IDeg at level 1 (54-69 mg/dL) (ETD: -1.7% [95% CI: -2.9, -0.5], P < .05) and level 2 (<54 mg/dL) (ETD: -1.3% [95% CI: -2.1, -0.5], P = .001). TAR was higher with IDeg compared with IGlar-100 at level 1 (181-250 mg/dL) (ETD: 4.0% [95% CI: 0.8, 7.3], P < .05) and level 2 (> 250 mg/dL) (ETD: 4.0% [95% CI: 0.8, 7.2], P < .05). The mean CV was lower with IDeg than that with IGlar-100 (ETD: -3.4% [95% CI: -5.6, -1.2], P < .05).CONCLUSION: For people with T1D suffering from recurrent nocturnal severe hypoglycemia, treatment with IDeg, compared with IGlar-100, results in a lower TBR and CV during the night at the expense of more TAR.
KW - Adult
KW - Blood Glucose Self-Monitoring
KW - Blood Glucose/analysis
KW - Continuous Glucose Monitoring
KW - Cross-Over Studies
KW - Diabetes Mellitus, Type 1/drug therapy
KW - Female
KW - Humans
KW - Hypoglycemia/chemically induced
KW - Hypoglycemic Agents/adverse effects
KW - Insulin Glargine/adverse effects
KW - Insulin, Long-Acting/therapeutic use
KW - Male
KW - Middle Aged
U2 - 10.1177/19322968231197423
DO - 10.1177/19322968231197423
M3 - Article
C2 - 37671755
SN - 1932-2968
VL - 19
SP - 390
EP - 399
JO - Journal of Diabetes Science and Technology
JF - Journal of Diabetes Science and Technology
IS - 2
ER -