T1 - Signal intensity of normal breast tissue at MR mammography on midfield
T2 - Applying a random coefficient model evaluating the effect of doubling the contrast dose
AU - Marklund, Mette
AU - Christensen, Robin
AU - Torp-Pedersen, Søren
AU - Thomsen, Carsten
AU - Nolsøe, Christian P.
PY - 2009/1/1
Y1 - 2009/1/1
N2 - Purpose: To prospectively investigate the effect on signal intensity (SI) of healthy breast parenchyma on magnetic resonance mammography (MRM) when doubling the contrast dose from 0.1 to 0.2 mmol/kg bodyweight. Materials and methods: Informed consent and institutional review board approval were obtained. Twenty-five healthy female volunteers (median age: 24 years (range: 21-37 years) and median bodyweight: 65 kg (51-80 kg)) completed two dynamic MRM examinations on a 0.6 T open scanner. The inter-examination time was 24 h (23.5-25 h). The following sequences were applied: axial T2W TSE and an axial dynamic T1W FFED, with a total of seven frames. At day 1, an i.v. gadolinium (Gd) bolus injection of 0.1 mmol/kg bodyweight (Omniscan) (low) was administered. On day 2, the contrast dose was increased to 0.2 mmol/kg (high). Injection rate was 2 mL/s (day 1) and 4 mL/s (day 2). Any use of estrogen containing oral contraceptives (ECOC) was recorded. Post-processing with automated subtraction, manually traced ROI (region of interest) and recording of the SI was performed. A random coefficient model was applied. Results: We found an SI increase of 24.2% and 40% following the low and high dose, respectively (P < 0.0001); corresponding to a 65% (95% CI: 37-99%) SI increase, indicating a moderate saturation. Although not statistically significant (P = 0.06), the results indicated a tendency, towards lower maximal SI in the breast parenchyma of ECOC users compared to non-ECOC users. Conclusion: We conclude that the contrast dose can be increased from 0.1 to 0.2 mmol/kg bodyweight, if a better contrast/noise relation is desired but increasing the contrast dose above 0.2 mmol/kg bodyweight is not likely to improve the enhancement substantially due to the moderate saturation observed. Further research is needed to determine the impact of ECOC on the relative enhancement ratio, and further studies are needed to determine if a possible use of ECOC should be considered a compromising factor, if an MRM is indicated in a young woman.
AB - Purpose: To prospectively investigate the effect on signal intensity (SI) of healthy breast parenchyma on magnetic resonance mammography (MRM) when doubling the contrast dose from 0.1 to 0.2 mmol/kg bodyweight. Materials and methods: Informed consent and institutional review board approval were obtained. Twenty-five healthy female volunteers (median age: 24 years (range: 21-37 years) and median bodyweight: 65 kg (51-80 kg)) completed two dynamic MRM examinations on a 0.6 T open scanner. The inter-examination time was 24 h (23.5-25 h). The following sequences were applied: axial T2W TSE and an axial dynamic T1W FFED, with a total of seven frames. At day 1, an i.v. gadolinium (Gd) bolus injection of 0.1 mmol/kg bodyweight (Omniscan) (low) was administered. On day 2, the contrast dose was increased to 0.2 mmol/kg (high). Injection rate was 2 mL/s (day 1) and 4 mL/s (day 2). Any use of estrogen containing oral contraceptives (ECOC) was recorded. Post-processing with automated subtraction, manually traced ROI (region of interest) and recording of the SI was performed. A random coefficient model was applied. Results: We found an SI increase of 24.2% and 40% following the low and high dose, respectively (P < 0.0001); corresponding to a 65% (95% CI: 37-99%) SI increase, indicating a moderate saturation. Although not statistically significant (P = 0.06), the results indicated a tendency, towards lower maximal SI in the breast parenchyma of ECOC users compared to non-ECOC users. Conclusion: We conclude that the contrast dose can be increased from 0.1 to 0.2 mmol/kg bodyweight, if a better contrast/noise relation is desired but increasing the contrast dose above 0.2 mmol/kg bodyweight is not likely to improve the enhancement substantially due to the moderate saturation observed. Further research is needed to determine the impact of ECOC on the relative enhancement ratio, and further studies are needed to determine if a possible use of ECOC should be considered a compromising factor, if an MRM is indicated in a young woman.
KW - Contrast media
KW - Dynamic
KW - Healthy volunteers
KW - Mammography
KW - MRI
UR - http://www.scopus.com/inward/record.url?scp=58149527085&partnerID=8YFLogxK
U2 - 10.1016/j.ejrad.2007.09.006
DO - 10.1016/j.ejrad.2007.09.006
M3 - Article
C2 - 17961948
AN - SCOPUS:58149527085
SN - 0720-048X
VL - 69
SP - 93
EP - 101
JO - European Journal of Radiology
JF - European Journal of Radiology
IS - 1
ER -