TY - JOUR
T1 - Fetal cardiac function and septal thickness in diabetic pregnancy
T2 - A controlled observational and reproducibility study
AU - Macklon, Nicholas S.
AU - Hop, Wim C.J.
AU - Wladimiroff, Jurly W.
PY - 1998/6
Y1 - 1998/6
N2 - Objective To determine the reproducibility of duplex Doppler waveform analysis and fetal cardiac interventricular septal thickness measurement and to compare these parameters in matched pregnancies with and without well-controlled maternal Type 1 diabetes at 18–20 weeks of gestation. Design A prospective blind twin cohort study and a blinded inter-observer and intra-observer agreement study. Setting A tertiary referral prenatal diagnostic unit within a university hospital. Results Good inter- and intra-observer agreement was found for the measurement of transvalvular peak flow velocities and the duration of ventricular ejection in the fetal heart. Inter-observer agreement for aortic flow acceleration rate was poor. M-mode measurement of interventricular septal thickness showed moderate reproducibility. The mean (SD) width of the interventricular septum in the fetuses of well controlled diabetic women was 2.1 mm (0.2 mm), and was significantly greater (P= 0.01) when compared with the corresponding value in matched controls [1.9 mm (0.2 mm)]. No cardiac functional differences were evident. Conclusions On-screen video analysis of Doppler cardiac flow waveforms and M-mode measurement of intraventricular septal thickness demonstrated good reproducibility. The fetuses of well controlled diabetic pregnancies demonstrated signs of altered cardiac morphology early in pregnancy, before any evident alterations in cardiac function.
AB - Objective To determine the reproducibility of duplex Doppler waveform analysis and fetal cardiac interventricular septal thickness measurement and to compare these parameters in matched pregnancies with and without well-controlled maternal Type 1 diabetes at 18–20 weeks of gestation. Design A prospective blind twin cohort study and a blinded inter-observer and intra-observer agreement study. Setting A tertiary referral prenatal diagnostic unit within a university hospital. Results Good inter- and intra-observer agreement was found for the measurement of transvalvular peak flow velocities and the duration of ventricular ejection in the fetal heart. Inter-observer agreement for aortic flow acceleration rate was poor. M-mode measurement of interventricular septal thickness showed moderate reproducibility. The mean (SD) width of the interventricular septum in the fetuses of well controlled diabetic women was 2.1 mm (0.2 mm), and was significantly greater (P= 0.01) when compared with the corresponding value in matched controls [1.9 mm (0.2 mm)]. No cardiac functional differences were evident. Conclusions On-screen video analysis of Doppler cardiac flow waveforms and M-mode measurement of intraventricular septal thickness demonstrated good reproducibility. The fetuses of well controlled diabetic pregnancies demonstrated signs of altered cardiac morphology early in pregnancy, before any evident alterations in cardiac function.
UR - http://www.scopus.com/inward/record.url?scp=0031746057&partnerID=8YFLogxK
U2 - 10.1111/j.1471-0528.1998.tb10182.x
DO - 10.1111/j.1471-0528.1998.tb10182.x
M3 - Article
C2 - 9647158
AN - SCOPUS:0031746057
SN - 1470-0328
VL - 105
SP - 661
EP - 666
JO - BJOG: An International Journal of Obstetrics and Gynaecology
JF - BJOG: An International Journal of Obstetrics and Gynaecology
IS - 6
ER -