Evaluation of systematic and random factors in measurements of fasting plasma glucose as the basis for analytical quality specifications in the diagnosis of diabetes. 3. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus

P. Hyltoft Petersen*, I. Brandslund, L. Jørgensen, M. Stahl, F. De Fine Olivarius, K. Borch-Johnsen

*Corresponding author af dette arbejde

    Publikation: Bidrag til tidsskriftArtikelForskningpeer review

    Abstract

    On behalf of the Danish Society of Clinical Endocrinology and the Danish Society of Clinical Chemistry we were commissioned to evaluate the influence of analytical and pre-analytical systematic and random factors on the diagnosis of diabetes, in order to provide a tool for conclusions on the analytical quality specifications needed to diagnose diabetes. A systems analysis was performed in accordance with the principles for evaluation of analytical quality specifications. The clinical setting was defined - diagnosis of diabetes in accordance with the WHO and ADA criteria with determination of fasting plasma glucose concentration (FPG) ≥7.0 mmol/L in two independent samples - with well-documented data on ln (loge)-Gaussian distribution of reference values from a low-risk population and values for within-subject biological variation taken from the literature. An investigation was made of the consequences for the clinical setting of assumed errors related to the measurement of FPG. Four approaches were investigated for a single sampling and measurement and also for two independent samples: one showing the percentage of healthy individuals who had values ≥7.0 mmol/L, one illustrating the origin of biological set-points for results ≥7.0 mmol/L, one showing the risk of being measured ≥7.0 mmol/L when the biological set-point is known, and one showing the combined bias and imprecision for assumed percentages of false-positive (FP), defined as measurements ≥7.0 mmol/L for the low-risk population and false-negative (FN), defined as measurements <6.4 mmol/L (the upper reference limit) for diabetics. This leaves a "grey zone" which includes the upper part of low-risk individuals, and defined by ADA and WHO as "impaired fasting glucose" (IFG). In the analysis, increasing systematic and random errors (combined analytical and pre-analytical) were assumed, and for each error condition the fractions of FP and FN were calculated. This gave plots from which the combined allowable systematic and random errors could be read off for pre-determined clinically acceptable fractions of FP and FN. The analysis does not distinguish between pre-analytical and analytical errors, as specified information on one of these is needed for specification of the other. The investigation provides a reliable basis for estimation of the needed analytical quality, and thereby for decisions about analytical quality specifications for analysis of FPG in relation to diagnosis of diabetes under optimized pre-analytical and analytical conditions. Consequences of deviations from these ideal conditions are illustrated in the figures, and should be considered for the different approaches with different performance conditions.

    OriginalsprogEngelsk
    Sider (fra-til)191-204
    Antal sider14
    TidsskriftScandinavian Journal of Clinical and Laboratory Investigation
    Vol/bind61
    Udgave nummer3
    DOI
    StatusUdgivet - 20 maj 2001

    Fingeraftryk

    Udforsk hvilke forskningsemner 'Evaluation of systematic and random factors in measurements of fasting plasma glucose as the basis for analytical quality specifications in the diagnosis of diabetes. 3. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus' indeholder.

    Citationsformater