TY - JOUR
T1 - Eight-year outcomes for patients with aortic valve stenosis at low surgical risk randomized to transcatheter vs. surgical aortic valve replacement
AU - Jørgensen, Troels Højsgaard
AU - Thyregod, Hans Gustav Hørsted
AU - Ihlemann, Nikolaj
AU - Nissen, Henrik
AU - Petursson, Petur
AU - Kjeldsen, Bo Juel
AU - Steinbrüchel, Daniel Andreas
AU - Olsen, Peter Skov
AU - Søndergaard, Lars
N1 - © The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology.
PY - 2021/8/7
Y1 - 2021/8/7
N2 - AIMS: The aims of the study were to compare clinical outcomes and valve durability after 8 years of follow-up in patients with symptomatic severe aortic valve stenosis at low surgical risk treated with either transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR).METHODS AND RESULTS: In the NOTION trial, patients with symptomatic severe aortic valve stenosis were randomized to TAVI or SAVR. Clinical status, echocardiography, structural valve deterioration, and failure were assessed using standardized definitions. In total, 280 patients were randomized to TAVI (n = 145) or SAVR (n = 135). Baseline characteristics were similar, including mean age of 79.1 ± 4.8 years and a mean STS score of 3.0 ± 1.7%. At 8-year follow-up, the estimated risk of the composite outcome of all-cause mortality, stroke, or myocardial infarction was 54.5% after TAVI and 54.8% after SAVR (P = 0.94). The estimated risks for all-cause mortality (51.8% vs. 52.6%; P = 0.90), stroke (8.3% vs. 9.1%; P = 0.90), or myocardial infarction (6.2% vs. 3.8%; P = 0.33) were similar after TAVI and SAVR. The risk of structural valve deterioration was lower after TAVI than after SAVR (13.9% vs. 28.3%; P = 0.0017), whereas the risk of bioprosthetic valve failure was similar (8.7% vs. 10.5%; P = 0.61).CONCLUSIONS: In patients with severe aortic valve stenosis at low surgical risk randomized to TAVI or SAVR, there were no significant differences in the risk for all-cause mortality, stroke, or myocardial infarction, as well as the risk of bioprosthetic valve failure after 8 years of follow-up.CLINICAL TRIAL REGISTRATION: URL: http://www.ClinicalTrials.gov. Unique identifier: NCT01057173.
AB - AIMS: The aims of the study were to compare clinical outcomes and valve durability after 8 years of follow-up in patients with symptomatic severe aortic valve stenosis at low surgical risk treated with either transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR).METHODS AND RESULTS: In the NOTION trial, patients with symptomatic severe aortic valve stenosis were randomized to TAVI or SAVR. Clinical status, echocardiography, structural valve deterioration, and failure were assessed using standardized definitions. In total, 280 patients were randomized to TAVI (n = 145) or SAVR (n = 135). Baseline characteristics were similar, including mean age of 79.1 ± 4.8 years and a mean STS score of 3.0 ± 1.7%. At 8-year follow-up, the estimated risk of the composite outcome of all-cause mortality, stroke, or myocardial infarction was 54.5% after TAVI and 54.8% after SAVR (P = 0.94). The estimated risks for all-cause mortality (51.8% vs. 52.6%; P = 0.90), stroke (8.3% vs. 9.1%; P = 0.90), or myocardial infarction (6.2% vs. 3.8%; P = 0.33) were similar after TAVI and SAVR. The risk of structural valve deterioration was lower after TAVI than after SAVR (13.9% vs. 28.3%; P = 0.0017), whereas the risk of bioprosthetic valve failure was similar (8.7% vs. 10.5%; P = 0.61).CONCLUSIONS: In patients with severe aortic valve stenosis at low surgical risk randomized to TAVI or SAVR, there were no significant differences in the risk for all-cause mortality, stroke, or myocardial infarction, as well as the risk of bioprosthetic valve failure after 8 years of follow-up.CLINICAL TRIAL REGISTRATION: URL: http://www.ClinicalTrials.gov. Unique identifier: NCT01057173.
U2 - 10.1093/eurheartj/ehab375
DO - 10.1093/eurheartj/ehab375
M3 - Article
C2 - 34179981
SN - 0195-668X
VL - 42
SP - 2912
EP - 2919
JO - European heart journal
JF - European heart journal
IS - 30
ER -