Spring til hovednavigation Spring til søgning Spring til hovedindhold

Comparison of 3-year local control using DAHANCA radiotherapy guidelines before and after implementation of five millimetres geometrical GTV to high-dose CTV margin

  • Ruta Zukauskaite*
  • , Morten Horsholt Kristensen
  • , Jesper Grau Eriksen
  • , Jørgen Johansen
  • , Eva Samsøe
  • , Lars Johnsen
  • , Camilla Kjær Lønkvist
  • , Cai Grau
  • , Christian Rønn Hansen
  • *Corresponding author af dette arbejde

Publikation: Bidrag til tidsskriftArtikelForskningpeer review

Abstract

INTRODUCTION: Treatment planning using a five-millimetre geometrical margin from GTV to high-dose CTV (CTV1) has been used in DAHANCA treatment centres since 2013. We aimed to evaluate changes in CTV1 volumes, local control (LC), and recurrence pattern after the implementation of five-millimetre geometrical margins nationally.

MATERIALS AND METHODS: 1,948 patients with pharyngeal, and laryngeal squamous cell carcinomas completed definitive IMRT-based treatment in 2010-2012 and 2013-2015 in three centres. The patient-specific margin was calculated as median surface distance from primary tumour GTV (GTV-T) to CTV1. Radiologically verified local recurrences were analysed using a centre of mass (COM) of the delineated recurrence volume, measuring the shortest distance between COM to GTV-T and CTV1 boundaries.

RESULTS: Median GTV-CTV1 was 0.9 (0.0-0.97) and 0.47 cm (0.4-0.5) for 2010-2012 and 2013-2015, respectively. Median CTV1 changed in three centres from 76, 28, 42 cm3 to 61, 53, 62 cm3 for 2010-2012 and 2013-2015, respectively. Local failures occurred at 247 patients during first three years after radiotherapy. The 3-year LC rate for 2010-2012 and 2013-2015 was 0.84 and 0.87 (p = 0.06). Out of 146 radiology-verified analysable local recurrences, 102 (69.9%) were inside the CTV1. In 74.6% and 91% of cases, the LRs were covered by 95% isodose in 2010-2012 and 2013-2015, respectively.

CONCLUSION: DAHANCA radiotherapy guidelines based on a geometrically generated isotropic CTV1 margin led to less variation in treatment volumes and between centres than previous guidelines. The transition towards consensus GTV-CTV1 margins did not influence local tumour control. The majority of local recurrences were inside CTV1 and covered by the prescription dose.

OriginalsprogEngelsk
Artikelnummer110284
TidsskriftRadiotherapy and Oncology
Vol/bind196
Tidlig onlinedato16 apr. 2024
DOI
StatusUdgivet - jul. 2024

Fingeraftryk

Udforsk hvilke forskningsemner 'Comparison of 3-year local control using DAHANCA radiotherapy guidelines before and after implementation of five millimetres geometrical GTV to high-dose CTV margin' indeholder.

Citationsformater